BASELAYER EDGE XA20


EDGE XA20 Modular Data Center
Outdoor or Indoor Deployable Modular Data Center that delivers up to 600 kW of Critical IT power and Economized Cooling for up to thirty-five (35) 52U Cabinets @ N• Engineered to meet NEMA 4 compliance standards for deployment in all global environments
Unit PUE Range
As low as 1.05
(Dependent upon Environmental and Operational Conditions)

Maximum Module Capacity
Maximum Available kW at 25 °F ΔT
@N
600 kW
@N+1
500 kW
@2N
300 kW

Maximum Module Density, kW/Cabinet
 
 
(35) 24″ (609 mm) Cabinets
@N
17.1 kW/Cabinet
@N+1
14.3 kW/Cabinet
@2N
8.5 kW/Cabinet

Security
Access Control
Open Compartmentalized Architecture, Enhanced Security Encryption, Versatile Interoperability, Proximity Card Readers (Keypad and Biometric Options Available), Layers of Physical & Logical Protection, Separate IT & Support Space Access
Cameras
Pre-wired for IP Based Cameras
Door Locks
Electronic Locks

Fire System
Dedicated Fire System
Externally Accessible Fire Control Panel, Pre-Discharge Alarm & Strobe Lights, Fire Pull Station, Abort Hold Button and Keyed Bottle Disconnects
Smoke Detection
Aspirating Smoke Detection
Fire Suppression
Clean Agent Fire suppression (Non-Ozone Depleting Agent)
Fire Rating
NFPA 72 Compliant and UL-Listed Fire Equipment
Exterior Dimensions US(Metric)
Length Width Height
42’ 8” (13.0 m) 33′ 6″ (10.2 m) 13’ 3” (4.0 m)

Interior Tech Space Dimensions US(Metric)
Length Width Height
41’ 8” (12.7 m) 21’ 0” (6.4 m) 9’ 4” (2.8 m)

IT Space Area (Usable)
645 ft2 (60 m2)
US (Metric)
Technology-agnostic design with 645 ft2 of IT space.
 
Cold Aisle = 52″ (1.3 m), Hot Aisle = 36″ (.91 m) (Standard Configuration)

Estimated Module
101,000 lbs. (45,812 kg) (Includes IT and Cooling Blocks)
Shipping Weight US (Metric)
(Excludes IT Cabinets and Equipment)

Standard IT Cabinets (Quantity)
(35) 24” (609 mm) Cabinets (Up to 52U)

Voltage/Frequency
400 V, 3-Phase, 50 Hz 480 V, 3-Phase, 60 Hz

Power Distribution (IT)
400 A Busways Standard; Up to 800 A per Busway (Optional)

Cooling Type
Outside Air (OSA) Economizer with Chilled Water Trim, Counterflow Chilled Water Coils
 
and High Efficiency Plug Fans with Electronically Commutated Motors (ECM)

Leak Detection
Strip Leak Detection
outdoor data center- edge front
outdoor data center- edge front
outdoor data center- edge front