loading

Loading

Baselayer Edge

BASELAYER® EDGE

The BASELAYER EDGE module is designed to meet high power density requirements for HPC, Cloud and Web Scale environments for both indoor and outdoor deployment.

XC-Series

green data center - EDGE D
XC10 / XC15
XC20
XC30
XC40
XC50

XA-Series

green data center - EDGE EA
XA10 / XA15
XA20
XA30
XA40
XA50

X1-Series

green data center - EDGE EA
X1

BASELAYER EDGE XC40


EDGE XC40 Data Module

Delivers up to 500kW of Critical IT power and Cooling for up to eighty-five (85) 52U racks Engineered to meet NEMA 4 compliance standards for deployment in all global environments Ships configuration tested from the factory with RunSmart Embedded providing access to key module sensors and controls via a web-based server Power and cooling redundancy thresholds are configurable through BASELAYER® RunSmart OS

Download XC40 Spec Sheet
Unit PUE Range
As low as 1.15
(Dependent upon Environmental and Operational Conditions)

Maximum Module Capacity*
 
Maximum Available kW
@N
 
500kW MAX CAPACITY

@N+1
 
500kW MAX CAPACITY

@2N
 
250kW MAX CAPACITY

Access Control
 
Compartmentalized Architecture, Role Based Access Control, Layers of Physical & Logical Protection, Separate Tech & Support Space Access

Fire System
Dedicated Fire System
Dedicated 4-wire loop to signaling devices and initiating devices, with all batteries, amplifiers, transponders provided for a fully addressable fire alarm system. Pre-Discharge Alarm & Strobe Light
Fire Rating
1 Hour
Download XC40 Spec Sheet
Exterior
Dimensions
US(Metric)
Length
Width
Height
42’ 8” (13.00m)
52’ 0” (15.85m)
13’ 3” (4.00m)

Interior Tech
Space Dimensions
US(Metric)
Length
Width
Height
41’ 8” (12.70m)
42’ 6” (9.91m)
9’ 4” (2.85m)

Number of Standard Cabinets
85 x 24” (609.6mm) Cabinets

Rack U
Up to 52U
Voltage/Frequency
480V, 3 Phase, 4 Wire, 60Hz
400V, 3 Phase, 3 Wire, 50Hz

Power Distribution (IT)Z
Up to 2000A per Busway

Cooling Mechanics
Chilled Water

Heat Removal
12 Fans/8 Coils

Leak Detection
Strip Leak Detection (4 total)
Download XC40 Spec Sheet
outdoor data center- edge front
outdoor data center- edge front
outdoor data center- edge front

DEPLOYMENT SCENARIO


BASELAYER EDGE units are configurable in many deployment scenarios. This deployment delivers up to 2.0 MW of Critical IT power and Cooling for up to eighty (80) 52U racks @ N redundancy.

BASELAYER deployments can consist of both power and data (IT) modules configured and tested from the factory with an enhanced integrated Module Control Unit (MCU) providing access to real-time module sensors.

Engineered to meet NEMA 4 compliance standards for deployment in all global environments.

Power and cooling redundancy thresholds, along with analytics and historic trending, are all available through BASELAYER RunSmart OS

outdoor data center deployment module
SPECIFICATIONS & PERFORMANCE
Unit PUE Range
As low as 1.15
(Dependent upon Environmental and Operational Conditions)

Total Product Installation Footprint
8,451 ft2 (785.5m2)

Critical IT Footprint
1,833 ft2 (170.4m2)

Access Control
Compartmentalized Architecture

Intelligent Control Interfaces
Customizable: Role Based Visibility, Warnings, Alarms, Thresholds & Control Set Points; BASELAYER RunSmart OS Integrates Both Modular and Legacy Data Center Infrastructure with IT Equipment

Dedicated Fire
Dedicated 4-wire loop to signaling devices and initiating devices, with all batteries, amplifiers, transponders provided for a fully addressable fire alarm system. Pre-Discharge Alarm & Strobe Light

Available (UI) User Interface
Visualizer – Desktop and Mobile, Business Reporting, API Provide Real-time Visibility, Control, Optimization, and Automation

CE
Compliant
Outdoor Compliance
NEMA 4
UL
UL 2755 Compliant
NFPA
Compliant